DSP_R_11 Tile Documentation

Config Bitmap

 
 
 
 
 
R
R
 
 
 
C
C
C
C
M
R
R
R
 
 
M
 
 
 
 
 
R
R
S
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
R
R
R
R
S
S
E
 
 
 
R
R
R
R
R
R
R
R
 
 
R
R
R
R
R
R
R
R
 
 
R
R
R
R
R
R
R
R
 
 
R
R
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Configuration Enums

Configuration enum ACC54_0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F90B0
ASYNC 1
SYNC -

Configuration enum ACC54_1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F91B0
ASYNC 1
SYNC -

Configuration enum ACC54_1.ROUNDHALFUP

Value F5B0
DISABLED -
ENABLED 1

Configuration enum ACC54_1.ROUNDRTZI

rounding mode

Value F6B0
ROUND_TO_INFINITE 1
ROUND_TO_ZERO -

Configuration enum ACC54_1.RSTCMUX

RSTC gating and inversion control

Value F50B0 F51B0
0 - -
INV 1 1
RSTC 1 -

Configuration enum ACC54_1.RSTOMUX

RSTO gating and inversion control

Value F52B0 F53B0
0 - -
INV 1 1
RSTO 1 -

Configuration enum ACC54_1.SFTEN

enable variable shifter controlled by SFTCTRL

Value F54B0
DISABLED -
ENABLED 1

Configuration enum ACC54_1.SIGN

select dynamic signedness or signedness controlled by parameters

Value F55B0
DISABLED -
ENABLED 1

Configuration enum ACC54_1.STATICOPCODE_EN

operation controlled by input pins or parameters

Value F56B0
DISABLED -
ENABLED 1

Configuration enum MULT18X36_1.MULT18X36

enable 18x36 multiply

Value F20B0
DISABLED -
ENABLED 1

Configuration enum MULT18X36_1.ROUNDHALFUP

Value F26B0
DISABLED -
ENABLED 1

Configuration enum MULT18X36_1.ROUNDRTZI

rounding mode

Value F27B0
ROUND_TO_INFINITE 1
ROUND_TO_ZERO -

Configuration enum MULT18X36_1.SFTEN

enable variable shifter controlled by SFTCTRL

Value F28B0
DISABLED -
ENABLED 1

Configuration enum MULT9_H0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F71B0
ASYNC 1
SYNC -

Configuration enum MULT9_H1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F73B0
ASYNC 1
SYNC -

Configuration enum MULT9_H2.RESET

selects synchronous or asynchronous reset for DSP registers

Value F75B0
ASYNC 1
SYNC -

Configuration enum MULT9_H3.RESET

selects synchronous or asynchronous reset for DSP registers

Value F77B0
ASYNC 1
SYNC -

Configuration enum MULT9_L0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F70B0
ASYNC 1
SYNC -

Configuration enum MULT9_L1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F72B0
ASYNC 1
SYNC -

Configuration enum MULT9_L2.RESET

selects synchronous or asynchronous reset for DSP registers

Value F74B0
ASYNC 1
SYNC -

Configuration enum MULT9_L3.RESET

selects synchronous or asynchronous reset for DSP registers

Value F76B0
ASYNC 1
SYNC -

Configuration enum PREADD9_H0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F61B0
ASYNC 1
SYNC -

Configuration enum PREADD9_H1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F63B0
ASYNC 1
SYNC -

Configuration enum PREADD9_H2.RESET

selects synchronous or asynchronous reset for DSP registers

Value F65B0
ASYNC 1
SYNC -

Configuration enum PREADD9_H3.RESET

selects synchronous or asynchronous reset for DSP registers

Value F67B0
ASYNC 1
SYNC -

Configuration enum PREADD9_L0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F60B0
ASYNC 1
SYNC -

Configuration enum PREADD9_L1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F62B0
ASYNC 1
SYNC -

Configuration enum PREADD9_L2.RESET

selects synchronous or asynchronous reset for DSP registers

Value F64B0
ASYNC 1
SYNC -

Configuration enum PREADD9_L3.RESET

selects synchronous or asynchronous reset for DSP registers

Value F66B0
ASYNC 1
SYNC -

Configuration enum REG18_H0_0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F84B0
ASYNC 1
SYNC -

Configuration enum REG18_H0_1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F85B0
ASYNC 1
SYNC -

Configuration enum REG18_H1_0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F86B0
ASYNC 1
SYNC -

Configuration enum REG18_H1_1.CEPMUX

CEP gating and inversion control

Value F10B0 F11B0
1 1 1
CEP - -
INV - 1

Configuration enum REG18_H1_1.CLKMUX

clock gating and inversion control

Value F12B0 F13B0
0 - -
CLK 1 -
INV 1 1

Configuration enum REG18_H1_1.GSR

if ENABLED primitive is reset by user GSR

Value F14B0
DISABLED 0
ENABLED 1

Configuration enum REG18_H1_1.MODE

REG18_H1_1 primitive mode

Value F14B0 F16B0
NONE 1 1
REG18_CORE - -

Configuration enum REG18_H1_1.REGBYPS

register enable or bypass

Value F15B0
BYPASS 1
REGISTER -

Configuration enum REG18_H1_1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F87B0
ASYNC 1
SYNC -

Configuration enum REG18_H1_1.RSTPMUX

RSTP gating and inversion control

Value F16B0 F17B0
0 - -
INV 1 1
RSTP 1 -

Configuration enum REG18_L0_0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F80B0
ASYNC 1
SYNC -

Configuration enum REG18_L0_1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F81B0
ASYNC 1
SYNC -

Configuration enum REG18_L1_0.RESET

selects synchronous or asynchronous reset for DSP registers

Value F82B0
ASYNC 1
SYNC -

Configuration enum REG18_L1_1.RESET

selects synchronous or asynchronous reset for DSP registers

Value F83B0
ASYNC 1
SYNC -